Technical Object Authorization Group - Client
- Technical Object Authorization Group
| I_UTILSINSTDDVCEANDINST.MANDT == T370B.MANDT I_UTILSINSTDDVCEANDINST.AUTHORIZATIONGROUP == T370B.BEGRU
|
Currency Key | I_UTILSINSTDDVCEANDINST.MANDT == TCURC.MANDT I_UTILSINSTDDVCEANDINST.CURRENCY == TCURC.WAERS
|
Equipment category | I_UTILSINSTDDVCEANDINST.MANDT == T370T.MANDT I_UTILSINSTDDVCEANDINST.EQUIPMENTCATEGORY == T370T.EQTYP
|
Higher-Level Installation | I_UTILSINSTDDVCEANDINST.HIGHERLEVELUTILSINSTALLATION == EANL.MANDT |
Country/Region of Manufacture - Client
- Country/Region of Manufacture
| I_UTILSINSTDDVCEANDINST.MANDT == T005.MANDT I_UTILSINSTDDVCEANDINST.MANUFACTURERCOUNTRY == T005.LAND1
|
Reason for blocking meter reading - Client
- Reason for blocking meter reading
| I_UTILSINSTDDVCEANDINST.MANDT == TE119.MANDT I_UTILSINSTDDVCEANDINST.METERREADINGBLOCKINGREASON == TE119.ABLSPERR
|
Meter Reading Unit | I_UTILSINSTDDVCEANDINST.MANDT == TE422.MANDT I_UTILSINSTDDVCEANDINST.METERREADINGUNIT == TE422.TERMSCHL
|
Control of perm. number of cust. MRs and autom. estimations - Client
- Control of perm. number of cust. MRs and autom. estimations
| I_UTILSINSTDDVCEANDINST.MANDT == TE438.MANDT I_UTILSINSTDDVCEANDINST.NMBROFALLWDMTRRDNGSCNTRLCODE == TE438.ABLESARTST
|
Plant | I_UTILSINSTDDVCEANDINST.MANDT == T001W.MANDT I_UTILSINSTDDVCEANDINST.PLANT == T001W.WERKS
|
Key of Primary Installation | I_UTILSINSTDDVCEANDINST.PRIMARYUTILITIESINSTALLATION == EANL.MANDT |
Storage location - Client
- Plant
- Storage location
| I_UTILSINSTDDVCEANDINST.MANDT == T001L.MANDT I_UTILSINSTDDVCEANDINST.PLANT == T001L.WERKS I_UTILSINSTDDVCEANDINST.STORAGELOCATION == T001L.LGORT
|
Type of Technical Object - Type of Technical Object
- Client
| I_UTILSINSTDDVCEANDINST.TECHNICALOBJECTTYPE == T370K.EQART I_UTILSINSTDDVCEANDINST.MANDT == T370K.MANDT
|
Foreign Key Check for IUID Type | I_UTILSINSTDDVCEANDINST.UNIQUEITEMIDENTIFIERSTRUCTYPE == TIUID_TYPE.IUID_TYPE |
Billing Class | I_UTILSINSTDDVCEANDINST.UTILITIESBILLINGCLASS == EAKLASSE.AKLASSE I_UTILSINSTDDVCEANDINST.MANDT == EAKLASSE.MANDT
|
Number of the billing schema - Client
- Number of the billing schema
| I_UTILSINSTDDVCEANDINST.MANDT == ESCH.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESBILLINGSCHEMA == ESCH.SCHEMANR
|
Equipment Number | I_UTILSINSTDDVCEANDINST.MANDT == EQUI.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESDEVICE == EQUI.EQUNR
|
Device category | I_UTILSINSTDDVCEANDINST.MANDT == MARA.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESDEVICECATEGORY == MARA.MATNR
|
Installation type | I_UTILSINSTDDVCEANDINST.MANDT == TE439.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESINSTALLATIONTYPE == TE439.ANLART
|
Gas Pressure Level at Installation Level (Grid) - Gas Pressure Level at Installation Level (Grid)
- Client
| I_UTILSINSTDDVCEANDINST.UTILITIESINSTGASPRSSRLVL == TE696.DRUCKSTUF I_UTILSINSTDDVCEANDINST.MANDT == TE696.MANDT
|
Voltage Level | I_UTILSINSTDDVCEANDINST.MANDT == TE369.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESINSTVOLTAGELEVEL == TE369.SPEBENE
|
Premise | I_UTILSINSTDDVCEANDINST.MANDT == EVBS.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESPREMISE == EVBS.VSTELLE
|
Rate Category | I_UTILSINSTDDVCEANDINST.MANDT == ETTA.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESRATECATEGORY == ETTA.TARIFTYP
|
Service Type | I_UTILSINSTDDVCEANDINST.MANDT == TECDE.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESSRVCPROVIDERROLE == TECDE.SERVICE
|
Temperature area | I_UTILSINSTDDVCEANDINST.MANDT == TE307.MANDT I_UTILSINSTDDVCEANDINST.UTILITIESTEMPERATUREAREA == TE307.TEMP_AREA
|
Activity reason | I_UTILSINSTDDVCEANDINST.MANDT == TE401.MANDT I_UTILSINSTDDVCEANDINST.UTILSDEVICEACTIVITYREASON == TE401.GERWECHS
|
Type of certification - Type of certification
- Client
| I_UTILSINSTDDVCEANDINST.UTILSDEVICECERTFNTYPE == TE359.BGLART I_UTILSINSTDDVCEANDINST.MANDT == TE359.MANDT
|
Seal code | I_UTILSINSTDDVCEANDINST.MANDT == TE937.MANDT I_UTILSINSTDDVCEANDINST.UTILSDEVICELEADSEALINGCODE == TE937.PLOMBE
|
Loss Determination Group - Client
- Loss Determination Group
| I_UTILSINSTDDVCEANDINST.MANDT == TE1001.MANDT I_UTILSINSTDDVCEANDINST.UTILSDEVICELOSSDETNGROUP == TE1001.LOSSDTGROUP
|
Modification reason - Client
- Modification reason
| I_UTILSINSTDDVCEANDINST.MANDT == TE791.MANDT I_UTILSINSTDDVCEANDINST.UTILSDEVICEMODREASON == TE791.UMBAUGR
|
Parametrization | I_UTILSINSTDDVCEANDINST.MANDT == TE927.MANDT I_UTILSINSTDDVCEANDINST.UTILSDEVICEPARAMETRIZATIONCODE == TE927.PARAMETR
|
Price Class | I_UTILSINSTDDVCEANDINST.MANDT == TE431.MANDT I_UTILSINSTDDVCEANDINST.UTILSDEVICEPRICECLASS == TE431.PREISKLA
|
Role of an Installation Within the Installation Group - Client
- Role of an Installation Within the Installation Group
| I_UTILSINSTDDVCEANDINST.MANDT == TE673.MANDT I_UTILSINSTDDVCEANDINST.UTILSINSTALLATIONGROUPROLE == TE673.INSTROLE
|
Grouping Type for Installation Group - Client
- Grouping Type for Installation Group
| I_UTILSINSTDDVCEANDINST.MANDT == TE672.MANDT I_UTILSINSTDDVCEANDINST.UTILSINSTALLATIONGROUPTYPE == TE672.INSTGRTYPE
|
Release Status for Installation Data - Client
- Release Status for Installation Data
| I_UTILSINSTDDVCEANDINST.MANDT == TEINFOREL.MANDT I_UTILSINSTDDVCEANDINST.UTILSINSTDATARELEASESTATUS == TEINFOREL.INFOREL
|
Deregulation status - Deregulation status
- Client
| I_UTILSINSTDDVCEANDINST.UTILSINSTDEREGULATIONSTS == TEDEREGSTAT.DEREGSTAT I_UTILSINSTDDVCEANDINST.MANDT == TEDEREGSTAT.MANDT
|
Reason for guarantee of supply - Client
- Reason for guarantee of supply
| I_UTILSINSTDDVCEANDINST.MANDT == TE759.MANDT I_UTILSINSTDDVCEANDINST.UTILSINSTGUAROFSUPREASON == TE759.NODISCONCT
|
Check Time Zone - Client
- Time Zone for EDM Objects
| I_UTILSINSTDDVCEANDINST.MANDT == TTZZ.CLIENT I_UTILSINSTDDVCEANDINST.UTILSINSTTIMEZONE == TTZZ.TZONE
|
Validation group for dependent validations - Client
- Validation group for dependent validations
| I_UTILSINSTDDVCEANDINST.MANDT == TE413.MANDT I_UTILSINSTDDVCEANDINST.UTILSREGDEPDNTVALDTNGROUP == TE413.PRUEFGR
|