I_UtilitiesDevice

Device | view: IEDEVICE | ATTR | Extraction: Not supported | Component: Device Management
Tables used: EGERHEQUIEQUZEGERS
Column Name Description
UtilitiesDevice FK Equipment Number
UtilsDeviceValidityEndDate Validity End Date of Device
Column Name Description
💲 Currency Key (Currency):
AcquisitionValue Acquisition Value
Column Name Description
Column Name Description
UtilsDeviceValidityEndDate Validity End Date of Device
UtilsDeviceValidityStartDate Validity Start Date of Device
UtilsDeviceInstallationDate Installation date
UtilsDeviceRemovalDate Device removal date
AcquisitionDate Acquisition date
UtilsDeviceLastLeadSealingDate Date of last lead sealing
UtilsDeviceModificationDate Modification date
LastChangeDate Last Changed On
Column Name Description
UtilsDeviceCertfnStatus Certification status Show values
SampleUtilsDeviceStatus Status of sample device Show values
UtilsDeviceCalibrnValdtyIsUsed Use calibration validity Show values
InstdUtilsDeviceIsCertifiable Certify installed devices Show values
Column Name Description Domain name
UtilsDeviceBscCatCombination Combination of a device category KOMBINAT
UtilitiesLogicalDeviceNumber Logical device number LOGIKNR
UtilitiesRegisterGroup Register Group GEGST
UtilsDeviceLocation Device Location TPLNR
UtilsDeviceGroup Device group DEVGRP
UtilsDeviceWindingGroup Winding group GEGST
UtilitiesPrepaymentMeterType Prepayment Meter PPM_METER
AdvancedMeteringSystem Advanced Metering System E_AMI_AMS
AdvancedMeterCapabilityGroup Advanced Meter Capability Group (AMCG) E_AMI_CAP_GRP
AssetManufacturerName Manufacturer of Asset TEXT30
ManufacturerSerialNumber Manufacturer's Serial Number CHAR30
ManufacturerPartTypeName Manufacturer model number TYPBZ
ConstructionYear Device Construction Year
SerialNumber Device GERNR
UniqueItemIdentifier Unique Item Identifier UII_CHAR72
UniqueItemIdentifierRespPlant Plant Responsible for UII WERKS
UtilsDeviceInOutGroup Input/output group GEGST
UtilsDeviceARCRCommandGroup ARCR Command Group GEGST
UtilsDeviceSampleLot Sample lot GEGST
UtilsDeviceMeasuredPressure Measured Pressure (Outlet Pressure) in Bars MESSDRCK
UtilsDeviceTransformationRatio Transformation ratio UEBERV
UtilsDeviceInspRelevanceCode Inspection relevance of device BESITZ
UtilsDeviceCertificationYear Certification Year JAHR
UtilsDeviceAdvncRplcmtYear Advance replacement year JAHR
UtilsDeviceCertificationNumber Certification number CHAR15
UtilsDeviceLastChangedByUser Name of Person Who Changed Object USNAM
UtilsDeviceInspPointGroup Inspection point group GEGST
UtilsDeviceInspectionNumber Device inspection number CHAR15
DvceIndivCertfnValdtyInYrs Individual cal. validity (years) of dev. subject to certif. ALLGVLZEIT
Master Data Relations Join Conditions
Technical Object Authorization Group
  • Client
  • Technical Object Authorization Group
  • I_UTILITIESDEVICE.MANDT == T370B.MANDT
  • I_UTILITIESDEVICE.AUTHORIZATIONGROUP == T370B.BEGRU
Currency Key
  • Client
  • Currency Key
  • I_UTILITIESDEVICE.MANDT == TCURC.MANDT
  • I_UTILITIESDEVICE.CURRENCY == TCURC.WAERS
Division
  • Client
  • Division
  • I_UTILITIESDEVICE.MANDT == TSPA.MANDT
  • I_UTILITIESDEVICE.DIVISION == TSPA.SPART
Equipment category
  • Client
  • Equipment category
  • I_UTILITIESDEVICE.MANDT == T370T.MANDT
  • I_UTILITIESDEVICE.EQUIPMENTCATEGORY == T370T.EQTYP
Country/Region of Manufacture
  • Client
  • Country/Region of Manufacture
  • I_UTILITIESDEVICE.MANDT == T005.MANDT
  • I_UTILITIESDEVICE.MANUFACTURERCOUNTRY == T005.LAND1
Plant
  • Client
  • Plant
  • I_UTILITIESDEVICE.MANDT == T001W.MANDT
  • I_UTILITIESDEVICE.PLANT == T001W.WERKS
Storage location
  • Storage location
  • Client
  • Plant
  • I_UTILITIESDEVICE.STORAGELOCATION == T001L.LGORT
  • I_UTILITIESDEVICE.MANDT == T001L.MANDT
  • I_UTILITIESDEVICE.PLANT == T001L.WERKS
Type of Technical Object
  • Client
  • Type of Technical Object
  • I_UTILITIESDEVICE.MANDT == T370K.MANDT
  • I_UTILITIESDEVICE.TECHNICALOBJECTTYPE == T370K.EQART
Foreign Key Check for IUID Type I_UTILITIESDEVICE.UNIQUEITEMIDENTIFIERSTRUCTYPE == TIUID_TYPE.IUID_TYPE
Equipment Number
  • Client
  • Equipment Number
  • I_UTILITIESDEVICE.MANDT == EQUI.MANDT
  • I_UTILITIESDEVICE.UTILITIESDEVICE == EQUI.EQUNR
Device category
  • Client
  • Device category
  • I_UTILITIESDEVICE.MANDT == MARA.MANDT
  • I_UTILITIESDEVICE.UTILITIESDEVICECATEGORY == MARA.MATNR
Activity reason
  • Client
  • Activity reason
  • I_UTILITIESDEVICE.MANDT == TE401.MANDT
  • I_UTILITIESDEVICE.UTILSDEVICEACTIVITYREASON == TE401.GERWECHS
Type of certification
  • Type of certification
  • Client
  • I_UTILITIESDEVICE.UTILSDEVICECERTFNTYPE == TE359.BGLART
  • I_UTILITIESDEVICE.MANDT == TE359.MANDT
Seal code
  • Client
  • Seal code
  • I_UTILITIESDEVICE.MANDT == TE937.MANDT
  • I_UTILITIESDEVICE.UTILSDEVICELEADSEALINGCODE == TE937.PLOMBE
Loss Determination Group
  • Client
  • Loss Determination Group
  • I_UTILITIESDEVICE.MANDT == TE1001.MANDT
  • I_UTILITIESDEVICE.UTILSDEVICELOSSDETNGROUP == TE1001.LOSSDTGROUP
Modification reason
  • Client
  • Modification reason
  • I_UTILITIESDEVICE.MANDT == TE791.MANDT
  • I_UTILITIESDEVICE.UTILSDEVICEMODREASON == TE791.UMBAUGR
Parametrization
  • Client
  • Parametrization
  • I_UTILITIESDEVICE.MANDT == TE927.MANDT
  • I_UTILITIESDEVICE.UTILSDEVICEPARAMETRIZATIONCODE == TE927.PARAMETR